Ultrasonic application equipment FUJI ULTRASONIC ENGINEERING

TEL.+81-053-464-6460  FAX.+81-053-465-3815
FontSize
  • S
  • M
  • L
Top > Technical Info > FAQ

FAQ


Q&A

  • Why ultrasonic?
  • How to purchase?
  • More about sample testing
 
  • More about explosion proof model
  • More about demo trial

Concentration Meter (FUD-1 series)

  • How to calibrate?
  • How to check the condition?
  • Any replacement item?
 
  • Any caution at installation?
  • Measurement errors

Viscosity Meter (FUV-1 series)

  • How to calibrate?
  • How to check the condition?
  • Any replacement item?
 
  • Measurement range?

Desktop Viscosity Meter (FCV-100)

  • Measurement range?
  • Temperature range?  
  • Correlation with B (rotation) type?
  • Data logging?
  • Option items
     
    • Minimum volume for measurement?
    • Customized sensor design?
    • Battery model?
    • Unstable measurement
    • More about tighter measurement




    Q&A


    Why ultrasonic?

    Because our unique principle (velocity for concentration meter & torsion mode vibration for viscosity meter), our products do not require any periodical parts replacement.  Moreover, periodical calibration is not required.  This provides minimum running cost for the owner.

    How to purchase?

    Please refer to the following chart (concentration meter).
    First contact
    please inform us “the measurement subject name”, “the concentration range” & “the temperature range”.  In case of no measuring experience, we would like to practice sample testing for your subject (free service).

    Specification checkplease inform us the hardware specifications such as “sensor material”, “flange size”, “explosion proof model” & “cable length”.

    Consideration
    Business discussion/presentation by official agent & free demo trial is available.

    Order
    It takes approximately 6 to 8 weeks for delivery.  Please check the specific delivery date when order issue.

    Installation
    Supervising by our official agent & at-site technical support by our engineer (charged service) are available.

    More about sample testing

    In case of that your subject is now for us, we practice sample testing with free of charge.   Please ask our local agent for the detail.  In general, sample testing requires approximately 2 weeks.

    More about explosion proof model

    The explosion proof repeater is required for explosion proof model even though the distance is less than 10m.  Please review the specifications of each products for explosion proof specification.

    More about demo trial

    Free demo trial is available in order to confirm actual performance at site.  Please ask the local agent for the demo unit.  The trail period is 3 weeks in general.




    Concentration Meter (FUD-1 series)

    How to calibrate?

    Adjustment with OFFSET & GAIN functions is available in case of finding the gap between the concentration reading on display & absolute (analysis) value.

    How to check the condition

    Please prepare water in vessel, and measure velocity & temperature of water.  When the gap between the standard water velocity & the present velocity reading is less than 2m/sec, the product as hardware works normally.  Also, please check transducer condition such as scratch, dent & stain.
    Standard water velocity

    Any replacement item?

    This product does not feature any item which can ware out or age.  However, we suggest to replace a power supply unit for the product over 10 years.  Also, replacement of an explosion proof repeater over 15 years is suggested.

    Any caution at installation?

    The common trouble on our product is measurement error due to bubble affection.  Bubble interrupts or reduces the ultrasonic pulse travelling in the solution.  We strongly suggest to review bubble condition at the installation position in advance.
    Instruction guide for FUD-1

    Measurement errors

    ?Bubble affection
    Bubbles in solution can be critical for measurement.  Please avoid bubble affection absolutely.
    ?Stain / Sludge / accretion
    Stain, sludge & accretion should cause reduction of ultrasonic pulse.  Periodical cleaning is suggested under these conditions.
    ?Noise affection
    Noise typically causes spikes on reading.  Please give proper countermeasure such as “changing GND and/or power source route”, “Cable re-wiring” & “noise filter”.




    Viscosity Meter (FUV-1 series)


    How to calibrate?

    Adjustment with OFFSET & GAIN functions is available in case of finding the gap between the concentration reading on display & absolute value.

    How to check the condition?

    Please check the viscosity reading on display under condition of air (around 0 mPa.S), water (0 to 2 mPa.S) & JIS standard oil (minimum gap).


    Any replacement item?

    This product does not feature any item which can ware out or age.  However, we suggest to replace a power supply unit for the product over 10 years.  Also, replacement of an explosion proof repeater over 15 years is suggested.

    Measurement range?

    FUV-1 features 3 types based on viscosity range as low viscosity (0-100mPa.S), middle viscosity (0-1,000mPa.S) & high viscosity (0-10,000mPa.S).   Temperature limitation for low & middle is 0-100 degree C, and for high is 0-50 degree C.




    Desktop Viscosity Meter (FCV-100)


    Measurement range?

    FCV-100 features 3 types based on viscosity range as low viscosity (0-100mPa.S), middle viscosity (0-1,000mPa.S) & high viscosity (0-10,000mPa.S).

    Temperature range?

    10 to 40 degree C.


    Correlation with B (rotation) type?

    Certain correlation can be found with B-type for Newtonian fluid theoretically.  However, it is uncertain for Non-Newtonian fluid due to different shearing speed.  FCV-100 has viscosity conversion function (liner compensation with 10 points data input) for this requirement.

    Data logging?

    RS232C communication software (CD) is bundled.  It is possible to store the log data (as text file) in your laptop with this software.  Moreover, you can make a real time graph for viscosity & temperature.

    Option items

    Carrying case, cramp stand & RS232C cable are available as extra charged option.  Please ask the local agent in detail.

    Minimum volume for measurement?

    With the extra option of the small volume vessel, measurement is available for 30 ml.

    Customized sensor design?

    Not available.

    Battery model

    Not available.

    Unstable measurement

    The followings are typical conditions of unstable measurement.  Please avoid these conditions for proper measurement.
    1. Incomplete immersing
    2. Unstable temperature
    3. Touching with side wall of the vessel
    4. Stain / accretion on the transducer
    5. Ununiformed viscosity (incomplete mixture) of the sample

    More about tighter measurement

    • Stable temperature condition with temperature controller (water bath)
    • Warm up time (20 to 30 min.)
    • Position (measuring condition) maintaining with cramp holder

    FUJI ULTRASONIC ENGINEERING
    1068 Iida-cho, Chuo-ku, Hamamatsu, Shizuoka 435-0028
    TEL.+81-53-464-6460  FAX.+81-053-465-3815
    主站蜘蛛池模板: 亚洲高清无在码在线无弹窗| 国产男女爽爽爽爽爽免费视频| 久久婷婷久久一区二区三区| 狠狠色狠狠色综合系列| 国产小视频在线看| 亚洲欧美一区二区三区电影| 蜜臀91精品国产高清在线观看| 国内xxxx乱子另类| 中文字幕在线看视频一区二区三区| 欧美大胆a级视频免费| 免费观看男男污污ww网站| 91在线丨亚洲| 国精无码欧精品亚洲一区| 中文字幕免费视频| 极品色天使在线婷婷天堂亚洲| 假山后面的呻吟喘息h| 视频一区精品自拍| 快点cao我要被cao烂了| 亚洲av无码专区在线观看下载| 男人j进美女p动态图片| 国产三级精品三级男人的天堂| 手机看片福利日韩国产| 好妈妈5韩国电影高清中字| 久久亚洲AV成人无码| 欧美亚洲国产成人高清在线| 人妻少妇乱子伦精品| 美日韩在线观看| 国产小视频在线观看网站| 91久久青青草原线免费| 少妇人妻在线视频| 久久久国产99久久国产久| 欧美一卡2卡3卡4卡免费| 亲胸揉胸膜下刺激网站| 美女胸又www又黄网站| 国产在线五月综合婷婷| 青青青青久久久久国产| 在线观看国产一区二区三区| 一进一出60分钟免费视频| 欧美日韩一区二区三区自拍 | 久久久久久久无码高潮| 李莫愁好紧好湿好滑|